A virtual machine boots on the destination cluster. A quick disk test produces a large number. The migration team puts a green check beside storage performance.

The useful question comes later: can the application meet its response time and batch deadlines while the other migrated VMs are busy?

Before the first production wave, agree on the workload, the conditions, and the evidence that will count as a pass. Then measure the source and destination against that agreement. A migration benchmark should give the application owner a reason to accept the destination.

Elvir Kuric’s Red Hat Developer walkthrough, updated on November 3, 2026, provides a containerized harness for running the Flexible I/O Tester (fio) across Linux VMs on Red Hat OpenShift Virtualization. It coordinates execution and collects results across guests. That is a useful foundation for a repeatable test campaign.

The decisions around those runs matter just as much as the command. Start with one representative guest, establish a comparison with VMware vSphere, and then add the concurrency the migration wave will bring.

Define acceptance before running FIO

Ask the application owner what becomes unacceptable when storage is slow. An interactive application might have a transaction response-time limit. A reporting service might need its overnight job finished before 06:00. A file service might have a sustained transfer requirement. Record the business condition first, then choose storage tests that help investigate it.

Write down these items before collecting results:

  • The workload: block sizes, read/write mix, access pattern, working set, and expected busy periods. Use application telemetry where it is available.
  • The required service: transaction latency, batch duration, or transfer rate, with an owner who can accept the result.
  • The test conditions: VM size, number of active guests, background work, and any maintenance condition included in the approval.
  • The failure conditions: I/O errors, missed application deadlines, or storage latency beyond an agreed limit at the required load.

For example, a team might require an order transaction to remain below 500 milliseconds at the 95th percentile during a representative busy hour. That is an illustrative application target, not an OpenShift requirement. An 8 KiB FIO operation cannot stand in for that transaction. The storage test helps determine whether the destination has enough capacity and where a slowdown starts.

Keep the source measurement too. If the existing platform already misses the business target, merely matching its performance will not close the acceptance question.

Make the source and destination comparable

Use disposable Linux test VMs with dedicated test disks on both platforms. Match the guest operating system, FIO version, vCPU count, memory, filesystem, test-file size, and workload parameters. Preserve the configuration and record the differences you cannot remove.

There are two useful comparisons. Holding the storage backend constant can help investigate differences in the virtualization path. Testing the actual source datastore against the planned destination storage answers the migration question. If both the hypervisor and storage change, describe the result as a comparison of the two complete environments.

On OpenShift, record the StorageClass, persistent volume claim (PVC) access mode and volume mode, storage driver version, VM disk configuration, and worker placement. On vSphere, retain the datastore and storage policy, virtual controller, and host placement. Include the backend’s protection, compression, deduplication, and provisioning settings in the run notes.

A PVC with volumeMode: Block can still hold a disk that the guest formats with XFS. Record both layers. The guest filesystem is part of the path the application will use.

The storage architecture guide covers the underlying design choices. This measurement is specifically about a VM’s workload disk. Keep control-plane storage validation as a separate check.

Start with a small set of workload profiles

Choose profiles that expose different constraints:

  • Small random I/O at low queue depth: explore latency when there are few outstanding requests.
  • A representative mixed workload: use the application’s observed block size and read/write ratio, then increase concurrency in steps.
  • Large sequential reads and writes: investigate throughput for workloads such as scans and file transfers.
  • A separate synchronous-write test: investigate workloads whose progress depends on durable commits, using the application’s actual flush behavior as the reference.

Keep the profile names and settings fixed across environments. Changing block size, queue depth, and VM count at once makes a regression difficult to explain.

For each profile, decide whether the goal is latency at a required load or the maximum load the configuration can sustain. Run those as distinct experiments. A saturation run is useful for finding a limit; the application still needs acceptable latency at its expected demand.

Run one guest test you can explain

This example uses one job, an 8 KiB random workload, and a 70 percent read mix. These are starting values for a lab, not a database workload model or a recommended setting for every VM.

Use a disposable Linux VM with FIO installed and its dedicated test filesystem already mounted at /mnt/fio. The example writes a 16 GiB file named fio-acceptance.bin; reserve additional filesystem free space. Confirm that this mount is the intended test disk and that the file can be overwritten. Run from a fresh working directory for each measurement so earlier results remain intact.

First, populate the file. Run the following in Bash inside the guest:

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
set -euo pipefail

mountpoint -q /mnt/fio || {
  printf '%s\n' 'Mount the disposable test filesystem at /mnt/fio first.' >&2
  exit 1
}
findmnt --mountpoint /mnt/fio
df -h /mnt/fio
mkdir -p fio-results
fio --version > fio-results/fio-version.txt

fio --name=prepare \
  --filename=/mnt/fio/fio-acceptance.bin \
  --size=16G --rw=write --bs=1M \
  --ioengine=libaio --direct=1 --iodepth=16 --numjobs=1 \
  --refill_buffers=1 --end_fsync=1 \
  --output-format=json --output=fio-results/prepare.json

Writing the entire file establishes a populated working set before the read test. It does not establish steady-state behavior for every storage system. Choose a working set and test duration that exercise the cache and sustained-load conditions relevant to the application; 16 GiB and a few minutes may be much too small.

Save this as vm-storage.fio in the same working directory:

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
[global]
filename=/mnt/fio/fio-acceptance.bin
size=16G
allow_file_create=0
ioengine=libaio
direct=1
iodepth=8
numjobs=1
time_based=1
runtime=300
ramp_time=30
refill_buffers=1
group_reporting=1
lat_percentiles=1
clat_percentiles=1
percentile_list=95:99:99.9

[mixed-8k]
rw=randrw
rwmixread=70
bs=8k

Check the job syntax, then run it:

1
2
3
fio --parse-only vm-storage.fio
fio --output-format=json+ \
  --output=fio-results/mixed-8k.json vm-storage.fio

The FIO manual defines these options. The 30-second ramp precedes 300 seconds of measurement. direct=1 bypasses the Linux guest’s page cache; it does not remove storage-system caches or impose synchronous commit semantics. lat_percentiles=1 includes submission and completion time. Inspect the achieved queue-depth distribution as well as the requested depth.

This job runs as fast as its concurrency permits. For acceptance at a specific offered load, create a separate rate-limited profile and keep that rate fixed across platforms. Preserve the saturation profile so you can also see how much room remains before latency rises.

Repeat each case at least three times as an initial check for variability. Retain every run. If the measurements drift or differ substantially, investigate the conditions and extend the experiment before choosing a representative result.

Coordinate the tests across VMs

Once the single-guest profile makes sense, use the fio-container harness to coordinate a larger campaign. It supports pre-created guests and automatic provisioning. Its plain SSH mode also supports Linux guests on vSphere, which gives the source and destination a common orchestration approach.

Pin the harness revision or container digest and record the resolved FIO job parameters. Translate the acceptance profile deliberately; running a harness with different defaults creates a different test. Keep the guest FIO version fixed too.

The harness’s filesystem mode formats the selected data devices, and raw mode writes directly to them. Use an isolated test namespace and disposable guests. Inspect the host and device mapping with the documented --dry-run --verbose invocation before executing a campaign. Its USE_TESTDIR mode targets the guest OS disk, so that mode answers a different question when the application’s data lives on another disk.

Keep the per-VM result files, the effective configuration, and the run log together. A combined summary is useful, but retain enough detail to find the one guest that missed the target.

Add the load the migration wave will bring

Increase the number of simultaneously active test VMs in controlled steps. For example, start with one, then four, then eight if those counts fit the planned estate. Record where the guests land; eight VMs on one worker exercise a different condition from eight spread across several workers.

At each step, compare every VM’s latency and achieved throughput with the baseline. Watch guest CPU and memory pressure, worker load, network utilization, and backend storage telemetry over the same timestamps. The VM observability post describes the distinction between platform visibility and what still needs measurement inside the guest.

Then introduce expected background work one condition at a time: a backup, an image import, or another application’s batch window. If maintenance performance is part of acceptance, test a supported live migration in the lab while the representative workload runs. Use the VM upgrade and evacuation checks to establish eligibility and spare capacity first.

An idle-cluster result applies to an idle cluster. Keep normal-load, background-load, and maintenance results separate so the application owner can see which operating conditions were accepted.

Read latency and throughput together

For each VM and profile, retain achieved I/O operations per second (IOPS), throughput, read and write latency percentiles, error status, and the measurement window. Check units before comparing exports.

IOPS only becomes comparable when the operation size and workload are specified. At 8 KiB per operation, 12,000 IOPS represents about 93.75 MiB/s of payload. That arithmetic says nothing about whether the application’s slowest requests are acceptable.

Keep read and write latency separate. A mixed workload can have healthy reads while writes miss the agreed limit. Check the slowest guest too; a cluster total can increase while one application gets worse.

Do not average p99 values across VMs or runs and label the result a fleet p99. Compare individual distributions, or combine compatible histograms with the appropriate sample counts. Preserve the underlying results so the calculation can be reviewed.

Choose the result that meets the required demand within the latency budget. If a higher queue depth raises IOPS while pushing latency past that budget, the extra IOPS do not satisfy acceptance. Record the first load level that fails and investigate its bottleneck before adding the next migration wave.

Finish with the application

Run a representative application test on the destination after the storage profiles pass. Include the transaction mix, dataset, concurrency, and background jobs that established the acceptance condition. Exercise the database’s real commit path where durability affects response time.

Record application errors and correctness alongside performance. A fast test that returns incomplete results has failed. Include a long enough window to observe the business job that matters, whether that is an interactive peak or an overnight batch.

Put the evidence in the migration change record: source and destination configurations, test definitions, per-VM results, relevant telemetry, application results, exceptions, and the owner’s decision. The rollback plan should name the acceptance failures that trigger a return and the latest time that decision can be made.

Keep the accepted test configuration for later storage, driver, image, and cluster changes. Repeating it turns the migration baseline into a way to detect regressions.

The solutions architect takeaway

  1. Agree on acceptance first. Tie the test to application demand and an observable failure condition.
  2. Preserve the comparison. Match guest workloads and document the infrastructure differences.
  3. Measure the busy environment. Add concurrent guests and expected background activity before accepting a wave.
  4. Keep latency beside throughput. Retain per-VM results and the conditions under which they were measured.
  5. Get application sign-off. Use the real transaction or batch job to make the migration decision.

Want help defining a performance acceptance test for your first migration wave? Bring the application targets and source measurements to your Red Hat account team before committing to the destination design.